25,640 BTU/H UNIT COOLER: Danfoss Optyma DACC RX L210.1A4/A1 low profile evaporator for walk-in coolers; 25,640 Btu/h at 25 °F SST and 10 °F TD with R448A.
AIR DEFROST: Off-cycle air defrost for coolers above freezing; no defrost heaters to wire or maintain.
MULTI-REFRIGERANT: Approved for R404A, R507A, R448A and R449A. Cross-rifled copper tubes and 6 fins per inch for efficient heat transfer.
QUIET, ROBUST BUILD: 3 x 315 mm (12.4 in) variable-speed capable, factory-balanced fan motors on 230 V single-phase; powder-coated aluminum cabinet with stainless steel brackets.
VERIFY BEFORE ORDERING: Connections 1/2 in inlet and 5/8 in outlet; expansion valve sold separately. Confirm the model 114U0005 (DACC RX L210.1A4/A1) and the 230 V supply before ordering.
Weight : 253.0 LBR
Model : 114U0005
25,640 BTU/H UNIT COOLER: Danfoss Optyma DACC RX L210.1A4/A1 low profile evaporator for walk-in coolers; 25,640 Btu/h at 25 °F SST and 10 °F TD with R448A.
AIR DEFROST: Off-cycle air defrost for coolers above freezing; no defrost heaters to wire or maintain.
MULTI-REFRIGERANT: Approved for R404A, R507A, R448A and R449A. Cross-rifled copper tubes and 6 fins per inch for efficient heat transfer.
QUIET, ROBUST BUILD: 3 x 315 mm (12.4 in) variable-speed capable, factory-balanced fan motors on 230 V single-phase; powder-coated aluminum cabinet with stainless steel brackets.
VERIFY BEFORE ORDERING: Connections 1/2 in inlet and 5/8 in outlet; expansion valve sold separately. Confirm the model 114U0005 (DACC RX L210.1A4/A1) and the 230 V supply before ordering.
Weight : 253.0 LBR
Model : 114U0005
Specifications
- Model: 114U0005, DACC RX L210.1A4/A1
- Capacity: 25,640 Btu/h, R448A, 25 °F SST, 10 °F TD
- Application: Cooler (MBP)
- Fans: 3 x 315 mm (12.4 in), 230 V / 1 Ph / 50-60 Hz, MCC 2.02 A
- Airflow at 60 Hz: 2,163 CFM
- Length: 73-1/8 in
- Cross-reference: BEL0190BS6AMA, RL6A195DDA
Mount below a flat ceiling with free air discharge and never over a door; slope the drain line and trap it outside the box. For installations with U.S. EPA restricted refrigerants, use only to service existing equipment. Confirm the model and the electrical supply before installing.
G114U0005
New
Data sheet
- Product Feature
- VERIFY BEFORE ORDERING: Connections 1/2 in inlet and 5/8 in outlet; expansion valve sold separately. Confirm the model 114U0005 (DACC RX L210.1A4/A1) and the 230 V supply before ordering.
- 25,640 BTU/H UNIT COOLER: Danfoss Optyma DACC RX L210.1A4/A1 low profile evaporator for walk-in coolers; 25,640 Btu/h at 25 °F SST and 10 °F TD with R448A.
- AIR DEFROST: Off-cycle air defrost for coolers above freezing; no defrost heaters to wire or maintain.
- MULTI-REFRIGERANT: Approved for R404A, R507A, R448A and R449A. Cross-rifled copper tubes and 6 fins per inch for efficient heat transfer.
- QUIET, ROBUST BUILD: 3 x 315 mm (12.4 in) variable-speed capable, factory-balanced fan motors on 230 V single-phase; powder-coated aluminum cabinet with stainless steel brackets.
- VERIFY BEFORE ORDERING: Connections 1/2 in inlet and 5/8 in outlet; expansion valve sold separately. Confirm the model 114U0005 (DACC RX L210.1A4/A1) and the 230 V supply before ordering.
- Weight
- 253.0 LBR
- Model
- 114U0005
- Origin
- USA