Danfoss OP-LJZ136D40N 6 HP LBP Condensing Unit R404A 208-230 V 1 Ph 60 Hz
$11,350.20
Price per Each
Price per Each
SKU
G115F0704
Danfoss OP-LJZ136D40N 6 HP LBP Condensing Unit R404A 208-230 V 1 Ph 60 Hz
LOW TEMPERATURE (LBP) CONDENSING UNIT: 6 HP Optyma unit for walk-in freezers and frozen food storage; 21,474 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
COMPRESSOR AND REFRIGERANTS: Maneurop NTZ136-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
MICROCHANNEL CONDENSER: 1 fan of 17-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
VERIFY BEFORE ORDERING: Connections 7/8 in suction and 1/2 in liquid. Confirm the model OP-LJZ136D40N and a 208-230 V single-phase 60 Hz supply before ordering.
Weight : 295.42 LBR
Volume : 24.24 FTQ
Model : LJZ136D40N
LOW TEMPERATURE (LBP) CONDENSING UNIT: 6 HP Optyma unit for walk-in freezers and frozen food storage; 21,474 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
COMPRESSOR AND REFRIGERANTS: Maneurop NTZ136-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
MICROCHANNEL CONDENSER: 1 fan of 17-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
VERIFY BEFORE ORDERING: Connections 7/8 in suction and 1/2 in liquid. Confirm the model OP-LJZ136D40N and a 208-230 V single-phase 60 Hz supply before ordering.
Weight : 295.42 LBR
Volume : 24.24 FTQ
Model : LJZ136D40N
Specifications
- Model: OP-LJZ136D40N, Danfoss code 115N0704, 115F0704
- Version: D40 with outdoor housing and full compressor protection
- Compressor: NTZ136-1, 208-230 V / 1 Ph / 60 Hz
- Fans: 1 x 17-3/4 in, 230 V / 1 Ph
- Replaces: 114N3356
Typical uses: walk-in freezers and frozen food storage. For installations with U.S. EPA restricted refrigerants, use only to service existing equipment. Confirm the model and the electrical supply before installing.
G115F0704
New
Data sheet
- Product Feature
- VERIFY BEFORE ORDERING: Connections 7/8 in suction and 1/2 in liquid. Confirm the model OP-LJZ136D40N and a 208-230 V single-phase 60 Hz supply before ordering.
- COMPRESSOR AND REFRIGERANTS: Maneurop NTZ136-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
- FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
- LOW TEMPERATURE (LBP) CONDENSING UNIT: 6 HP Optyma unit for walk-in freezers and frozen food storage; 21,474 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
- MICROCHANNEL CONDENSER: 1 fan of 17-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
- VERIFY BEFORE ORDERING: Connections 7/8 in suction and 1/2 in liquid. Confirm the model OP-LJZ136D40N and a 208-230 V single-phase 60 Hz supply before ordering.
- Weight
- 295.42 LBR
- Volume
- 24.24 FTQ
- Model
- LJZ136D40N
- Origin
- Mexico