Danfoss OP-LJZ048D40N 2 HP LBP Condensing Unit R404A 208-230 V 1 Ph 60 Hz
LOW TEMPERATURE (LBP) CONDENSING UNIT: 2 HP Optyma unit for walk-in freezers and frozen food storage; 7,150 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
COMPRESSOR AND REFRIGERANTS: Maneurop NTZ048-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
MICROCHANNEL CONDENSER: 1 fan of 13-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
VERIFY BEFORE ORDERING: Connections 1/2 in suction and 3/8 in liquid. Confirm the model OP-LJZ048D40N and a 208-230 V single-phase 60 Hz supply before ordering.
Weight : 187.39 LBR
Volume : 5.07 FTQ
Model : LJZ048D40N
LOW TEMPERATURE (LBP) CONDENSING UNIT: 2 HP Optyma unit for walk-in freezers and frozen food storage; 7,150 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
COMPRESSOR AND REFRIGERANTS: Maneurop NTZ048-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
MICROCHANNEL CONDENSER: 1 fan of 13-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
VERIFY BEFORE ORDERING: Connections 1/2 in suction and 3/8 in liquid. Confirm the model OP-LJZ048D40N and a 208-230 V single-phase 60 Hz supply before ordering.
Weight : 187.39 LBR
Volume : 5.07 FTQ
Model : LJZ048D40N
Danfoss OP-LJZ048D40N Condensing Unit Low Temp for Freezers
This item will replace various brands and models including but not limited to:
Replaces:LCZ022E40N, LJZ048D40N, 114N3343,114N6725, 115N0678, LCZC0151UWF300N, 115F0678
Fits:
G115F0678
New
Data sheet
- Product Feature
- VERIFY BEFORE ORDERING: Connections 1/2 in suction and 3/8 in liquid. Confirm the model OP-LJZ048D40N and a 208-230 V single-phase 60 Hz supply before ordering.
- COMPRESSOR AND REFRIGERANTS: Maneurop NTZ048-1 hermetic reciprocating compressor with polyolester oil; approved for R404A, R452A.
- FACTORY EQUIPPED: Receiver, filter drier, sight glass, KP1 low pressure switch, high pressure cartridge switch, crankcase heater, rotolock valves and full electrical box.
- LOW TEMPERATURE (LBP) CONDENSING UNIT: 2 HP Optyma unit for walk-in freezers and frozen food storage; 7,150 BTU/h with R404A at -13 °F evaporating and 95 °F ambient.
- MICROCHANNEL CONDENSER: 1 fan of 13-3/4 in; uses up to 30% less refrigerant than fin-and-tube condensers. D40 version with outdoor housing and full compressor protection.
- VERIFY BEFORE ORDERING: Connections 1/2 in suction and 3/8 in liquid. Confirm the model OP-LJZ048D40N and a 208-230 V single-phase 60 Hz supply before ordering.
- Weight
- 187.39 LBR
- Volume
- 5.07 FTQ
- Model
- LJZ048D40N
- Origin
- Mexico